Showing posts with label Chromatography. Show all posts
Showing posts with label Chromatography. Show all posts

February 13, 2015

FORENSIC GAS CHROMATOGRAPHY FOR LAWYERS

Last week, I completed a short course in gas chromatography. Completing the course reminded me of what Stephen Covey used to say: “To know and not to do is really not to know.” He is so right. It’s one thing to know the law of blood and urine testing. It’s a very different thing to know the science of blood and urine testing. To know the science, you have to do the science, and lawyers typically do not have the opportunity to do the science. Now, however, lawyers get to do the science of gas chromatography in a short course presented by the Amercian Chemical Society.

The course, Forensic Chromatography Theory and Practice, is held in Chicago at the Axion Analytical Laboratories & Training Institute. Axion is the training arm for the American Chemical Society. The president of Axion, Lee Polite, Ph.D., is a leading authority in chromatography and serves as the primary instructor for the course.

WP_20150121_011

The 40-hour course consists of both lectures and labs. The lectures feature analogies which make chemistry understandable to even the least scientific lawyers. During the lectures, participants learn the scientific principles underlying the operation of the gas chromatograph. They also learn the parts of the instrument and the multitude of variables which must be set correctly for the instrument to produce an accurate result.

The labs are hands-on. Class participants run tests with known and unknown substances and learn to interpret the printed chromatograms. Students manipulate testing conditions to understand how those conditions affect results. Class participants also calibrate the instrument, use the associated software to program a calibration curve, and even take apart the injectors and columns.

This course also has a lawyering component. Instructors Justin McShane and Josh Lee apply the science of gas chromatography to the litigation of DUI/OVI cases involving blood/urine tests. They explain how to spot and exploit the plethora of conditions which may compromise test results. They also demonstrate a direct examination of a gas chromatography expert, as well as a cross examination of an opposing expert.

This forensic chromatography course has now been presented 14 times, and approximately 250 lawyers have completed the course. Ten of those lawyers have been from Ohio.

Participating in this course was enlightening and encouraging. Before this course, I felt knowledgeable about the law related to blood testing and urine testing in Ohio, but I did not feel as confident about the science. After taking this course, I feel like I actually understand the science behind blood and urine testing. I also feel like I can immediately apply that new knowledge in the courtroom, and I’m very much looking forward to my next DUI/OVI case with a blood or urine test.

Continue Reading...

December 14, 2014

The Basics of Blood Alcohol Testing by Gas Chromatography - Part I

September 19th, 2014 Allen Trapp Posted in Blood Test, Chemical Test |

The first stage of sample testing is the injection of the sample into the injector port. The sample is introduced into the injector port with a syringe or an exterior sampling device known as a pipette. The injector port is a hollow, glass-lined cylinder that is heated to 150-250°C which causes the sample to vaporize.

Most blood alcohol analyses are performed via headspace gas analysis as opposed to direct injection. A small amount (approximately 0.10 milliliters) of blood is diluted with water to about 1.0 milliliter in volume. The sample is placed in a sample vial and the cap is crimped and placed in an auto sampler with an incubating chamber set at a constant temperature. When the sample has reached equilibrium (when the rate of ethanol evaporation equals the rate of condensation in the sample vial), a sample of the gas above the liquid is withdrawn and injected into the gas chromatograph.

At this stage of the analysis Henry’s Law is in effect. Henry’s Law is a chemical principle that describes therelationship of volatile compounds in dilute aqueous solution at equilibrium.  Next, the vapors of the sample are carried into the column by a carrier gas.  The transportation of the vapors by the carrier gas, usually hydrogen, helium, or nitrogen is frequently referred to as the mobile phase. The carrier gas flows into the injector port, through the column, which is maintained by a temperature controlled oven, and then into the detector. The solutes travel through the column at a rate primarily determined by their physical properties, and the temperature and composition of the column. The column is packed or coated. This is commonly referred to as the stationary phase.

Written by Allen Trapp who is board certified by the National College for DUI Defense and the author of Georgia DUI Survival Guide Visit Website

You can follow any responses to this entry through the RSS 2.0 feed. You can leave a response, or trackback from your own site.

AddThis Social Bookmark Button
Continue Reading...

December 10, 2014

The Basics of Blood Alcohol Testing by Gas Chromatography - Part II

September 19th, 2014 Allen Trapp Posted in Blood Test, Chemical Test |

The various solutes travel through the column at different rates. The fastest moving solute exits (elutes) the column first then is followed by the remaining solutes in corresponding order. After the compounds have been eluted from the end of the column, they must be detected, one at a time. As each solute elutes from the column, it enters the heated detector. An electronic signal is generated upon interaction of the solute with the detector. The size of the signal is recorded by a data system and is plotted against elapsed time to produce a chromatogram.

The plot created by this process is called a chromatogram. The size of the signal is proportional to the amount of a compound in the sample. In conjunction with the data recorder, an integrator is frequently used to provide measurements of the height of the compound’s signal and the time that it took for the compound to elute through the column and reach the detector.  While many types of detectors exist, the most common detector used for the blood alcohol analysis is the flame ionization detector. The flame ionization detector simply burns each organic compound as it elutes from the column. As the compound burns, it produces an electrical signal. The electrical signal is displayed as a “peak” with a known retention time. The period of time between injection and reaching the detector is referred to as the retention time.

The retention time of a compound alone is insufficient to identity of compound. The retention time of a known compound must be compared to the retention time of the unknown compound to determine if the known compound also exists in the testing sample. By comparing the retention time of the compound to a known standard, the compound can be identified. Identifying the compound is the qualitative portion of the analysis.

The concentration of alcohol in a sample is measured by comparing the size of the peak produced by the testing sample to the size of the peak produced by different known concentrations of alcohol.   Measurement of the amount of the compound in the sample is the quantitative portion of the analysis.  Each compound has a different retention time with a particular mobile phase, stationary phase, and temperature. If testing conditions change, identifying the compound is not possible. Therefore, the instrument must be periodically tested with a known specimen to ensure the testing conditions have not changed and the calibration of instrument remains intact.

Written by Allen Trapp who is board certified by the National College for DUI Defense and the author of Georgia DUI Survival Guide Visit Website

You can follow any responses to this entry through the RSS 2.0 feed. You can leave a response, or trackback from your own site.

AddThis Social Bookmark Button
Continue Reading...

Links

Developed in partnership with SanFran Coders.

Blogroll

The acronyms DUI, DWI, OMVI and OVI all refer to the same thing: operating a vehicle under the influence of alcohol or drugs. The most commonly used terms are DUI, an acronym for Driving Under the Influence, and DWI, an acronym for Driving While Impaired.
© Copyright 2010 - 2015 MY OVI | Developed by San Fran Coders